日韩精品一区二区三区久久综合|久久久久久久久久久无码|日韩欧美精品一中文字幕|久久尤物免费一区二区三区

Welcome to ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd website!

Product | Contact | 中文

Professional manufacturer of
medical wire harness

+86-13929208661

Hot search: High frequency electric knife wireNegative plate connecting wireBlood oxygen wire

News

Technical support Position: Home > News > Technical support

Safety requirements for processing of medical wiring harness terminals

Date: 2021-03-30 Visited: 422

Medical wiring harness terminals are processed by a stamping die. The main process equipment for precision stamping parts processing is the stamping die, because the medical wiring harness terminals are completed by the relative movement of the upper and lower dies. If the operator's fingers continue to enter or stay in the mold closed area, it will bring serious threats to their personal safety.


Guide parts Guide posts and guide sleeves are the most widely used guide parts of medical wiring harness terminals. Guide pillar, guide sleeve clearance should be smaller than the blanking clearance because its role is to ensure that the punch and concave die in the stamping work with accurate clearance. The guide post should be arranged far away from the module and the pressing plate, so that the operator's arm does not have to cross the guide post to send material, otherwise it will seriously threaten their personal safety.


The terminal die support and clamping parts of medical wiring harness include upper and lower formwork, die handle, convex and concave die fixing plate, backing plate, limiter, etc. The base part of the die is the upper and lower formwork, and the other parts are respectively installed and fixed on it. The plane size of the template, especially the front and back direction should be adapted to the parts, too large or too small are not conducive to operation. In order to facilitate the production of some molds, it is necessary to set up a backing plate under the die frame. At this time, the plate is best connected with a screw between the template, and the thickness of the two plates should be absolutely equal. In order to avoid the template fracture, the spacing of the pad should not be too large, so as to be able to prevail.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
大荔县| 富民县| 灌云县| 松阳县| 镶黄旗| 孟津县| 泽州县| 湖州市| 密山市| 天津市| 南溪县| 卢氏县| 江西省| 武宁县| 涟水县| 堆龙德庆县| 庆元县| 阜阳市| 玉门市| 建昌县| 佛冈县| 绥滨县| 镇原县| 元朗区| 米泉市| 四平市| 青岛市| 兰州市| 五台县| 合作市| 神农架林区| 盖州市| 留坝县| 容城县| 霸州市| 垦利县| 凯里市| 新平| 大化| 泗水县| 穆棱市|